Black & Decker POWER TO GO CP120XB Manuale Utente

Pagina di 13
• DO NOT OPERATE portable electric tools near flammable liquids or in gaseous or
explosive atmospheres. Certain components in these tools normally spark, and the
sparks might ignite fumes.
• EXTENSION CORDS. Make sure your extension cord is in good condition. When using an
extension cord, be sure to use one heavy enough to carry the current your product will draw.
An undersized cord will cause a drop in line voltage resulting in loss of power and
overheating. The following table shows the correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next heavier gage. The smaller the gage
number, the heavier the cord.
• OUTDOOR USE EXTENSION CORDS. When tool is used outdoors, use only extension
cords intended for use outdoors and so marked.
SAFETY GUIDELINES / DEFINITIONS
DANGER: Indicates an imminently hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING: Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury.
CAUTION: Used without the safety alert symbol indicates potentially hazardous situation
which, if not avoided, may result in property damage.
WARNING: RISK OF UNSAFE OPERATION. When using tools or equipment, basic safety
precautions should always be followed to reduce the risk of personal injury. Improper operation,
maintenance or modification of tools or equipment could result in serious injury and property
damage. There are certain applications for which tools and equipment are designed. Black &
Decker strongly recommends that this product NOT be modified and/or used for any application
other than for which it was designed. Read and understand all warnings and operating instructions
before using any tool or equipment.
SAVE THESE INSTRUCTIONS
2
Minimum Gage for Cord Sets
Volts 
Total Length of Cord in Feet
120V
0-25
26-50
51-100
101-150
(0-7,6m)
(7,6-15,2m)
(15,2-30,4m)
(30,4-45,7m)
240V
0-50
51-100
101-200
201-300
(0-15,2m) (15,2-30,4m)
(30,4-60,9m)
(60,9-91,4m)
Ampere Rating
More
Not more
American Wire Gage
Than
Than
0   -
6
18
16
16
14
6   -
10
18
16
14
12
10 -
12
16
16
14
12
12 -
16
14
12
Not Recommended
CPI20XB_ManualEN_041307.qxp  6/25/07  2:07 PM  Page 2