PNEG-552 100 Series Dryer
5. Dryer Pre-Start Checks
Before the dryer is filled, thoroughly inspect the unit and check the operation of the dryer as follows.
Inspect the Metering Rolls
Figure 5A Asco Safety Shut Off Valve
Open all metering roll access doors and inspect each compartment for any bolts, nuts or other foreign 
material, that may cause possible jamming of the metering rolls.
Set Control Switches
Moisture Control Switch
OFF
Moisture Control Thermostat
200°
Load Switch
OFF
Unload Switch
OFF
Fan Switch
OFF
Burner Switch
OFF
Out of Grain Timer
1 MINUTE (Reset to 8 Minutes after testing)
Load Delay
30 SECONDS
Unload Delay
30 SECONDS
Metering Roll Speed
LOW AND HIGH SPEED SETTINGS PUT ON ZERO
Dry Timer
60 MINUTES
Cool Timer
20 MINUTES
Unload Timer
10 MINUTES
Mode Switch
CONTINUOUS FLOW
Before attempting to operate the dryer make sure all safety shields are in place, 
all bottom clean-out and rear access doors are closed and all personnel are 
clear of the dryer.