BENDIX TCH-008-031 Dépliant

Pagina di 1
Technical 
Bulletin
Bulletin No: TCH-008-031-A
Effective Date:  11/5/99
Cancels:  NA
Page: 1 of 1
Subject:
AD-2 AIR DRYER CAUTION NOTE UPDATE
In addition to the caution notes printed in the AD-2 Service Manual and Installation Instruction Sheets the
following procedures must be adhered to before servicing the AD-2 Air Dryer.
Failure to do so could result in personal injury.
1.  Drain all reservoirs completely.
2.  Loosen the air line to the control port of air dryer and allow the
trapped air to escape to atmosphere.   After the air escapes,
remove the control line from the air dryer.
3.  Loosen the delivery line from the delivery port or outlet of the
air dryer.  After the pressure drops, remove the delivery line.
Loosen the delivery check valve from this port to relieve any
trapped air above the desiccant plate assembly.
4.  Remove any exhaust silencers or the exhaust check valve cover
from the base of the air dryer.  Using a hex socket and wrench,
loosen the purge valve assembly and allow any trapped air to
escape.  Slowly unscrew the purge valve and remove it.
5.  Check all ports to insure that air is not trapped in the air dryer
by powdered desiccant material.
Air Dryer End Cover Removal Procedure
Warning 
- The AD-2 Air Dryer cartridge contains a high spring
load.  When replacing the AD-2 Air Dryer cartridge or performing
any maintenance requiring end cover removal follow the procedure
outlined below.
End Cover Removal
Review all caution notes in the Service Data Manual, Instruction
Sheets and those listed above.
1.  Loosen the three cap screws on the end cover and turn the
retaining clamps aside (cap screws may be left finger tight).
2.  Locate the notch in the air dryer shell.  While pushing the end cover up into the dryer, insert the blade of a
screwdriver in the notch and slowly pry out the retaining ring. If the cartridge bolt has loosened the cartridge
spring may exert a force on the end cover retaining ring making removal of the retaining ring and end cover
difficult.  This spring force will prohibit the end cover moving up into the dryer shell when pushed up.
Warning:  This same force can also cause the end cover to come out of the air dryer shell unexpectedly
during the removal process.  Exercise extreme caution to prevent bodily injury.
3.  Do not stand or lay directly under the end cover while servicing.  Assure adequate clearance between the end
cover and other surfaces to prevent hand injury if the end cover dislodges rapidly during removal.
4.  Proceed with maintenance procedures.
Bolt
End Cover
AD-2 Air Dryer
Delivery
Check
Valve
Control
Port
Spring
Cap Screws
Retaining Ring
Exhaust Check
Valve Cover
Purge Valve
Assembly