5. USING THE OPERATION PANEL (BASIC OPERATIONS) 
 
 
KE-430D, BE-438D 
33 
5-2. Setting the program number 
The program number is set to 0 (feed home position check) 
at the time of shipment from the factory. 
1. Press the   or 
 key (1) to select the program 
number. 
•  The program number will flash in the PROGRAM No. 
display (2). 
2.  Depress the foot switch to the 2nd step. 
•  The feed mechanism will move to the home position 
and the program number will be accepted. 
•  The program number will stop flashing and illuminate 
steadily. 
Note: 
Once the setting is complete, be sure to carry out the 
steps in "5-5./5-6. Checking the sewing pattern" to check 
that the needle drop position is correct. 
 
 
 
 
5-3. Setting the X-scale and Y-scale 
The scales are set to 100 (%) at the time of shipment from 
the factory. 
1. Press the SELECT key (1) so that the X-SCALE 
indicator (2) (for X-scale setting) or the Y-SCALE 
indicator (3) (for Y-scale setting) is illuminated. 
•  The setting value (%) will display in the menu display 
(4). 
* When memory switch no. 402 is set to "ON", the 
settings will be displayed in units of mm. 
2. Press the   or    key (5) to set the scale (20 - 200). 
•  The program number will flash in the PROGRAM No. 
display (6). 
3.  Depress the foot switch to the 2nd step. 
•  The feed mechanism will move to the home position 
and the scale will be accepted. 
•  The program number will stop flashing and illuminate 
steadily. 
Note: 
Once the setting is complete, be sure to carry out the 
steps in "5-5./5-6. Checking the sewing pattern" to check 
that the needle drop position is correct.
 
 
 
 
5-4. Setting the sewing speed 
The sewing speed is set to 2000 (rpm) at the time of 
shipment from the factory. 
1.  Press the SELECT key (1) until the SPEED indicator (2) 
illuminates.  
• The setting value (rpm) will display in the menu 
display (3).   
2. Press the   or    key (4) to set the sewing speed. 
(Sewing speed setting values 
KE-430D:  400  -  3200, 
BE-438D: 400 - 2700) 
 
 
4436Q
4437Q
2nd step 
2nd step 
4438Q