Bosch Appliances Home Security System D7412G Manuale Utente

Pagina di 142
D9412G/D7412G | Program Entry Guide | 6.0 RADXAUX1
EN | 122
Bosch Security Systems | 1/04 | 47775E
Enable Ext Modem
Default:
No
Selection:
Yes or No
Yes
Enable SDI Address 88 for use with an
external modem.
No
Disable SDI Address 88 for use with an
external modem.
Setting this item to Yes instructs the control panel
that SDI Address 88 is enabled for use with an
external modem. For further information on Local
RPS programming, see the RPS Operation Manual.
Setting this item to Yes disables
Enhanced Communication and SDI RAM
for use over a LAN or WAN.
Answer Armed
Default:
7
Selection:
0 to 15
0
No answer when all areas are Master
Armed.
0 to 15
The control panel answers the phone
after the specified number of rings
when all areas are Master Armed.
Determines the number of rings after which the
external modem automatically answers a call if all
areas are Master Armed.
Answer Disarmed
Default:
7
Selection:
0 to 15
0
No answer when any area is Perimeter
Armed or Disarmed.
0 to 15
The control panel answers the phone
after the specified number of rings
when any area is Perimeter Armed or
Disarmed.
Determines the number of rings after which the
external modem automatically answers a call if any
area is Perimeter Armed or Disarmed.
RAM Line Monitor
Default:
No
Selection:
Yes or No
This item is not yet implemented. Keep this item set
to No.
Seize Relay
Default:
No
Selection:
Yes or No
This item is not yet implemented. Keep this item set
to No.
Modem Init String
Default:
ATE0
Selection:
A to Z (capital letters only), 0 to 9,
[SPACE], ! “ # $ % & ‘ ( ) * + , - . / : ;
< = > ? @ [ \ ] ^ _
Determines which initialization string the control
panel sends to the external modem when the control
panel powers up.
0101
0101
0101
If special characters are required, this
item can only be programmed
successfully from RPS. The D5200
Programmer only allows the characters
shown in the Modem Init String
default/selections.
RAM Dial String
Default:
ATDT
Selection:
Not available
This item is not yet implemented.
6.5
Enhanced Communications
Enhanced communications is the ability to
communicate by some other means than the
standard digital dialer. In this section, programmable
parameters allow you to define up to four separate
enhanced communication paths to which events can
be routed. To route an event (such as an Alarm or
Trouble) to an enhanced communication path,
additional programming must also be completed in
Section 2.3 Routing and Section 2.4 Enhanced Routing.