XLT 020111
Repairing Units - Removing Rivets
Only a certified HVAC tech should work on the units. We do not want owners opening the units for their 
own safety. 
1. Unplug the WhisperKOOL unit.
2. Remove the WhisperKOOL unit from the wall mounting and set it on a sturdy workbench. 
3. Drill out the rivets on the top panel that hold the case together, using a 5/32 (size) drill bit. This will 
destroy the rivets.
4. Remove the top off of unit, and carefully remove the insulation (if any) from the top. 
5. When replacing the panel, you can use rivets or small metal 6-32 3/8” Phillips Pan Head Screws. It is 
recommended to locate any necessary parts at your local hardware store prior to the service.
Consumer Care Program
The  Consumer  Care  Program  is  designed  to  expedite  the  shipment  of  a  replacement  unit  to  your 
location quickly in order to get your cellar cooling again.
This program involves contacting our Customer Service department to purchase a replacement unit as 
the quickest solution. The unit is tested in our controlled environment and is ready for immediate use.
Complete details of our program including pricing are available by contacting our Customer Service 
department.