BENDIX BW2234 Manuale Utente

Pagina di 14
2
FIGURE 2 - BENDIX
® 
AD-IS
®
 AIR DRYER AND RESERVOIR SYSTEM CHARGE CYCLE 
The Bendix
®
 AD-IS
®
 PuraGuard
®
 oil coalescing air dryer 
has an identical appearance to the standard AD-IS
®
 air 
dryer, but contains a coalescing media at the inlet of the 
desiccant bed.  The coalescing media provides a higher 
level of oil removal over the standard AD-IS air dryer.  
The AD-IS PuraGuard oil coalescing air dryer has all of 
the same functions as the standard AD-IS air dryer and is 
used in applications where lower oil concentration levels 
are required.
Important!  When servicing, note that standard AD-IS 
air dryers or air dryer cartridges may be serviced with 
PuraGuard oil coalescing air dryers or cartridges, however, 
PuraGuard oil coalescing air dryers or cartridges must only 
be serviced with like replacements.  
Note: Unless otherwise stated in this manual, AD-IS air 
dryer and reservoir systems refers to both the standard and 
PuraGuard
 
oil coalescing air dryer and reservoir systems.
The function of the pressure protection valves is to protect 
each reservoir from a pressure loss in the other reservoir or 
a pressure loss in an air accessory.  Each of the pressure 
protection valves in the AD-IS
 
air dryer and reservoir 
systems may have different pressure settings. These are 
factory set and must not be changed or adjusted.  
The air dryer and reservoir system consists of a “spin on” 
desiccant cartridge secured to a base assembly.  The 
base assembly contains a delivery check valve assembly, 
COMPRESSOR
GOVERNOR
DESICCANT 
BED
DELIVERY 
CHECK VALVE 
(OPEN)
PRIMARY
PORT (PRI)
PURGE VALVE
(CLOSED)
TURBO 
CUT-OFF 
VALVE
(OPEN)
ENGINE 
TURBO
UNLOADER 
PORT 
SUPPLY 
PORT
PRIMARY
RESERVOIR
PRESSURE 
PROTECTION 
VALVES
AUXILIARY PORTS
(TO ACCESSORIES)
SEE
NOTE 1
Note 1:
The Bendix
®
 AD-IS
® 
air dryer and reservoir system 
purge piston has a purge control channel drain. This 
allows any condensation in this area to fl ow past a 
diaphragm in the top of the purge piston and out 
through a channel in the middle of the central bolt of 
the purge assembly to be drained. During the purge 
cycle this drain is closed.
SAFETY
VALVE
PURGE 
RESERVOIR 
DRAIN VALVE
SECONDARY
RESERVOIR
SECONDARY
PORT (SEC)
PURGE 
RESERVOIR
PURGE 
ORIFICE
OIL COALESCING FILTER 
(BENDIX
®
 AD-IS
®
 PURAGUARD
®
 
OIL COALESCING AIR DRYER)
A
D
C
B
PURGE 
CONTROL 
CHANNEL
DIAGRAM SHOWS ALL PRESSURE 
PROTECTION VALVES OPEN.