Adapta Valve Installation   
Locate the cold water supply under the sink.
Reverse Osmosis Module Mounting
Step 13 Determine best location for the RO module to be mounted to allow  
for future system maintenance.  The parts bag has 2 self  tapping 
screws.  Using a Phillips screwdriver, screw them into the cabinet 
wall 10 1/2”  apart and 16” from the bottom of the cabinet.
Step 10
Step 12  Attach adapta valve as illustrated in the three photos above, choosing the confi guration that 
fi ts your plumbing.  (When attaching the adapta valve to straight pipe threads, use Tefl on 
tape on the threads).   The white tube from  inlet side of RO module will be cut to length and 
attached later in the installation.
Do not cut any RO system tubes at this time.
Note:
Caution: Water supply line to the system must be from the cold water supply line only.  Hot 
water will severely damage your system.
Confi guration for 3/8”  
compression fi ttings  
Confi guration for 1/2”  
compression fi ttings  
Hot
Supply
Cold
Supply
 
Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
Step 11