For open array scanners you should also consider the following 
points:
Mounting Platform: The platform must be mechanically secure 
and capable of supporting the mass and inertia of the open array 
scanner. The complete unit weighs: 48" scanner - 30 kg (66.2 lb); 
72" scanner - 33.4 kg (73.7 lb).
The site must be clear of ropes and moving rigging.
Sufficient clearance must be allowed to fully open the open array 
pedestal for maintenance.
Mounting surface: sailboats
The scanner unit can be installed on a mast platform, an arch, or a 
bridge structure. Make sure that the platform surface is flat and the 
scanner unit drain hole (radome scanners) is not obstructed. 
Raytheon recommends that radome scanner units are best suited for 
sailboat operation as open array systems are more difficult to protect 
from ropes and sails.
For sailboat installations, Raytheon offers a universal mast mount kit 
for each radome scanner type. This optional mount is used to fit a 
radome scanner to a flat surface on a mast with a minimum diameter 
of 60 mm (2½ in). When using the mast mount kit, appropriate 
hardware should be used for the style and structure of the mast aboard 
the vessel. Typically, the scanner will be mounted near the first set of 
mast spreaders. If there is any doubt concerning the appropriate type 
of hardware, consult your boat dealer or representative for their 
recommendations.
Depending on the type of sailboat, a radar scanner guard should be 
installed if the sails could touch the scanner or platform. Without a 
proper radar guard the mounting platform and the radar scanner could 
be severely damaged.
Mounting surface: power boats
On many small vessels the scanner unit can be installed on a mast 
platform, an arch, or a bridge structure, but take care to follow the 
scanner site guidelines, particularly regarding height. If necessary, 
construct a radar mounting platform to obtain a sufficiently high 
mounting position. Make sure that the platform surface is flat and the 
scanner unit drain hole (radome scanners) is not obstructed. Ensure 
the platform is strong enough to support the maximum shock loads 
likely to occur.