Description
 
Channel Vision’s 15dB power injected inline amplifier provides the lowest induced noise figure available and is 
designed with the future in mind. Unlike other RF amplifiers, the C-0315 features a bi-directional return path for 
12VDC IN                    RF INPUT
Channel Vision
MULTI-ROOM AUDIO VIDEO TECHNOLOGY
CVT-15PIA
5-42MHz RETURN PATH PASS
54-1000MHz FORWARD PATH
3dB LOW NOISE AMPLIFIER
15dB GAIN
                   OUT-PWR
Cable or
Antenna
12VDC IN                    RF INPUT
Channel Vision
MULTI-ROOM AUDIO VIDEO TECHNOLOGY
CVT-15PIA
5-42MHz RETURN PATH PASS
54-1000MHz FORWARD PATH
3dB LOW NOISE AMPLIFIER
15dB GAIN
                   OUT-PWR
Cable or
Antenna
HS-3
CVT-PI
880
DC Blocker
Standard Wiring Layout 
Layout with Power Injector 
C-0315 
C-0315 
Instructions
 
Step 1: Mount amplifier. 
Step 2: Connect cable or antenna signal to the INPUT jack. 
Step 3: Connect OUTPUT jack to distribute signal to all the TV’s in the house. 
Step 4: Connect power to 12VDC input, or use PIA (power injector) for remote power capability.  Note: must use 
DC passive splitters. 
 
 
 
Please Note: 
The unused trunk line connector of the last outlet device in each trunk line MUST BE TERMINATED using a 
75
Ω terminator (model 2101).
 
Specifications
 
Parameter                              Condition              Min            Typ         Max 
Gain
                                        f=54MHz               13.5            14.5         15.5 
                                                f=1000MHz           14.0            15.5         17.0 
Flatness                                  54-1000MHz             -              +/-0.8          - 
Insertion Loss                        5-40MHz                -1.5               -            -0.5 
Return Loss IN                      5-40MHz                   -              -18           -14 
                                                54-750MHz               -              -20           -16 
                                                750-1000MHz           -              -16           -14 
Return loss OUT                    5-40MHz                   -              -18           -14 
                                                54-750MHz               -              -20           -16 
                                                750-1000MHz           -              -16           -14 
Tap - Tap Isolation                54-1000MHz             -                 -               - 
2nd Order Input Intercept            -                       80                 -               - 
3rd order input intercept
              -                       60                 -               - 
Composite Second Order              -                         -                 -            -60 
Composite Triple Beat                  -                         -              -70           -60 
Noise Figure                           54-60MHz                 -                3            3.5 
                                                60-750MHz               -              2.4           3.0 
                                                750-1000MHz           -                3            4.0 
Hum Modulation                           -                         -                -             -70 
Return Path Level                 5-27MHz                   -                -             60 
                                                27-40MHz                 -                -             40 
RFI Isolation                          5-1000MHz               -                -             -130 
Warning 
To prevent fire or shock hazard, do not expose this appliance to rain or moisture