properly attach the console cable.
Booting Without the Overlay 
File
If you cannot 
telnet
 into the switch and Linux fails to boot, it is likely that a change saved by 
zsync
 has left the switch in an inaccessible state. To allow users to recover from mistakes saved 
in the overlay file system, a boot argument of 
–i
 passed to the 
init
 process will stop the 
untarring of the saved overlay files. As a result, the system boots to the factory-shipped 
configuration. 
 1. Connect through the console port. During boot up, the system displays the Linux boot 
string. Linux/PPC load: for 5 seconds. During the 5 second pause, enter the boot option 
-i
 and press Return 
Linux/PPC load: root=/dev/ram init=/sbin/init -i 
 2. Initiating the 
–i 
option of 
zbootcfg
zbootcfg –d 1 –i 
 3. Reboot the system. After the reboot, clear the 
–i 
option from the boot string. Enter the 
following command: 
zbootcfg –d 1 
 4. The reboot command will also take 
-i 
as an option and pass it to the Linux boot, 
reboot -i  
 5. When the system boots, the overlay file system is returned to the factory-installed 
configuration. At this point, you have a few options.
Caution: All changes you have made and saved prior to the 
zsync
 command 
will be lost when the command executes. 
 a) Enter 
zsync,
 and the factory-installed system will be restored to your flash.
 b) Restore particular files from the existing overlay. Use the 
zmnt
 command to mount 
the overlay in a designated directory and copy back just the changes you want to keep 
from the existing overlay. 
For example, if you wanted to recover your /etc/hosts file from the existing 
overlay, use zmnt to mount the overlay in a designated directory, like 
/tmp
then copy /
tmp/etc/hosts
 to 
/etc/hosts
. Lastly, use 
zsync
 to save your 
changes (as follows). 
zmnt /tmp 
cp /tmp/etc/hosts /etc/hosts 
zsync /etc/hosts 
 6. Reboot the system. 