Network Connectivity Troubleshooting
No Connection
If the port LED is lit on the front panel, the switch has established a physical connection and the 
problem is a network configuration error. Check to see if both devices are configured to be on the 
same network (ex. 10.0.0.xxx) and that the subnet mask is set correctly.
Diminished Network Throughput
Depending on how the switch is configured, throughput problems can reflect configuration errors 
in the network topology.
If the Spanning Tree Protocol (STP) is not enabled, it is possible for broadcast loops to occur 
which can stress the network. The 
tcpdump
 (See the Ethernet Switch Blade User’s Guide for 
more information) utility is a widely used network troubleshooting tool which can display 
network traffic according to user-defined filters, which can help to troubleshoot problems such as 
broadcast loops. The 
tcpdump
 utility is included with the switch’s OA environment.
If STP is enabled, be sure to identify ports which were automatically blocked by the STP daemon 
to prevent broadcast loops.
A network diagram can be useful in isolating network loops.
Connecting to Devices with Fixed Port Speeds 
Verify that switch and the connected devices are set to the same port speed setting, otherwise 
diminished or no connections can be made. If devices connected to the Ethernet Switch Blade are 
connected at a fixed Full Duplex, high error rates or sporadic connectivity can be observed. It is 
recommended that all devices connected to the Ethernet Switch Blade be set to auto-negotiate.
External Fault LED
The EXT FLT LED indicates that communications could not be established with one or more 
remote partner devices on an active port or ports. Ports which were configured to be up (via 
ifconfig
), but do not have remote partner devices attached, can cause the EXT FLT LED to be 
lit, even if there are no hardware problems with the switch.
The 
OA
 
zlc
 command can be used to check the status of individual ports and also to manipulate 
how the EXT FLT LED is managed (globally or on a per-port basis). By default, the EXT FLT 
LED is a global indicator. Use the 
zlc
 command to change how the LED is managed, to help 
isolate external fault indications to a particular port.
Before acting on an EXT FLT LED indication, make sure the configuration for the switch reflects 
how the chassis is populated with expected device configurations. For example, if a “default” 
configuration was used on the switch to bring up all ports on startup, but not all of those ports 
Ethernet Switch Blade User's Guide