Znyx Networks bh5700 Manuale Utente

Pagina di 359
VRRP
Since most end nodes use default router addresses, the change of the default router address during 
a switch failover would require the end nodes to reconfigure.  Layer 3 switches that failover must 
maintain the default router address to maintain the end node's IP transparent failover. The Virtual 
Router Redundancy Protocol (VRRP, RFC 2338) running in the Surviving Partner switches 
provides transparent movement of the default router address. VRRP maintains the notion of a 
Master switch and one or more Backup switches. This group of switches presents a virtual router 
IP address that can be used by hosts on that net as their default route.
If a Backup switch determines the Master switch is no longer available, one of the Backup 
switches will assume the role as Master. Physically, each switch maintains a link to the local 
network. Only the Master switch answers to the default gateway, and the hosts on that net have 
no need to relearn the router address.
In an HA configuration, the goal is to avoid any single point of failure. VRRP provides a good 
mechanism to provide a static route for a local network, but a true HA configuration must also 
provide redundant connections for the host. Providing a virtual router for the local network is not 
enough. Take the simple case of two hosts on the local network with a connection to the virtual 
router. Each host needs a connection to each physical switch participating in VRRP. In the 
simplest configuration, each host would have one connection to the networkAn HA solution 
would include redundant connections from each host to each switch in the virtual router.
Combining the features of Surviving Partner on the switches and HA bonding drivers on the hosts 
allows implementation of this true HA configuration.
zlmd
In addition to complete switch failover, single link failure must be properly handled. The Link 
Monitor Daemon zlmd, monitors the link status of each port. If a link goes down, zlmd 
communicates with the VRRP daemon (vrrpd) to change its priority. Changing the VRRP 
priority results in movement of switching functionality. By combining zlmd with the zlc 
application, links connected to hosts that have not failed can be deterministically moved to the 
new master switch if desired. Supported modes include:
switch - The switch with the greatest number of UP links becomes the Master for all 
VLANs under HA management.
Vlan - The switch with the greatest number of UP links in that particular VLAN becomes 
the Master for that particular VLAN. If the switch has additional VLANs, they each 
change independently.
Port The Master will remain the Master for that particular VLAN until all ports in that 
VLAN are down. The Backup then becomes the new Master for that VLAN. Failed links 
move their connectivity through the Backup Switch and the switch interconnect to reach 
the Master Switch. This option alleviates the need to move all nodes to a new switch just 
because a single link goes down.
NOTE: All modes require inclusion of the interconnect in the VLAN. The ISL 
connection between the two Base switches is port 23 for the Ethernet Switch Blade. The 
ISL connection between the two fabric slots in port 51.