Appendix C   Intelligent Platform Management Interface 
The Ethernet Switch Blade provides Intelligent Platform Management Interface (IPMI) support. 
IPMI circuitry provides:
The communication channel between the Baseboard Management Controller (BMC) and the 
CPU for management.
Data storage, SDRR, FRU, access.
Sensor readings.
IPMI circuitry on the Ethernet Switch Blade peripheral management controller (PMC) provides 
three I
2
C compatible serial interfaces:
I
2
C Port 0
Connects to the BMC on an Alarm or System card. The bus is called 
IPMB. Via this connection the PMC can send status events, SDR ’s and 
FRU information to the BMC. It can also receive commands and control 
information from the BMC.
I
2
C Port 1
Connects to the Ethernet Switch Blade CPU and the “spare” SEEPROM.
I
2
C Port 2
Connects to the boot and run time SEEPROMs as well as the switch 
silicon. 
ISwitch-ShMC Interaction
Switch reports state changes to ShMC.
If event reporting is enabled, an event will be generated by the switch whenever a sensor 
threshold is crossed.
Policy is enforced by the ShMC.
Typical ShMC policy is to remove back-end power from a FRU that has crossed a threshold.
M States
M0
No power and hot swap handle open
M1
No communications. (Wait in M1 until hot swap ejector is closed)
M2
FRU announces its presence to the ShMC and awaits activation permission
M3
Activation
M4
Operational state (command issued to enable back-end power)