Znyx Networks bh5700 Manuale Utente

Pagina di 359
Version 2.x supports three FRU Inventory Device Commands:
Get FRU Inventory Area Info
Read FRU Data
Write FRU Data
The spare SEEPROM space is allocated as follows:
Spare SEEPROM Space Allocation
Space for
Start address
End address
Size
Notes
VPD
0
0x3FF
0x400 (1Kbytes)
FRU
0x400
0x13FF
0x1000 (4kbytes)
Parameters
0x1400
0x17FF
0x400 (1 Kbytes)
Attribute
0x1800
0x37FF
0x2000 (8 
Kbytes)
Table C.8: SEEPROM Space
IPMB Override/Local Status - Event Data 3 for the IPMB link
IPMB Override Status Data
Bit(s)
Type
Notes
7
IPMB B Override State
0=Override state, bus isolated; 1= Local Control state - IPM 
Controller determines state of bus
6:4
IPMB B Local Status
0=No Failure. Bus enabled if no override in effect; 
1=Unable to drive clock HI; 2=Unable to drive data HI; 
3=Unable to drive clock LO; 4= Unable to drive data LO; 
5= Clock low time out; 6=under test; 7=Undiagnosed 
communications failure
3
IPMB A Override State
0=Override state, bus isolated; 1= Local Control state - IPM 
Controller determines state of bus
2:0
IPMB A Local Status
0=No Failure. Bus enabled if no override in effect; 
1=Unable to drive clock HI; 2=Unable to drive data HI; 
3=Unable to drive clock LO; 4= Unable to drive data LO; 
Ethernet Switch Blade User's Guide
release  3.2.2j
page  354