Vogelzang International Mountaineer Woodstove VG650ELG Manuale Utente

Pagina di 18
Page 6 
/ VG650ELG MOUNTAINEER™
VGZ-025 / 100105.0
PIPE CONNECTOR INSTALLATION
1. The crimped end of the stovepipe fits inside
the stove flue collar. Install additional pipe and
elbow with the crimped end towards the stove.
This will allow any condensation in the flue to
run back into the firebox.
2. Horizontal pipe runs must slope upwards
towards the chimney at least 1/4” per foot of
horizontal run.
3. You must have at least 18 inches of clearance
between any horizontal piping and the ceiling.
4. The pipe cannot extend into the chimney flue
(figure 4).
5. Secure pipe/elbow sections with three (3) sheet
metal screws at each joint to make the piping
rigid.
6. It is recommended that no more than two (2)
90
° bends be used in the stovepipe installation.
The use of more than two 90
°  bends may
decrease the amount of draw and possibly cause
smoke spillage. Where possible, use only
corrugated (nonadjustable) elbows. These
provide a better seal.
7. The connector pipe must not pass through an
attic or roof space, closet, or any concealed
space, or floor, ceiling, wall or combustible
construction. (See Chimney Connector Sys-
tems & Clearances, page 17). A UL 103 HT
Listed chimney must  be used from the first
penetration of ceiling or wall to the chimney
cap. Never use single wall connector pipe as
a chimney - a house fire could result.
Fig. 4 – Stovepipe/Flue Connections
CORRECT
WRONG
WRONG
NOTE: STOVE PIPE IS 
NOT INCLUDED. TO
PURCHASE, VISIT YOUR LOCAL HARDWARE,
HOME OR BUILDING CENTER. SEE
“LOCATING STOVE” PAGE 4  FOR ADDITIONAL
SPECIFICATIONS.
DAMPER INSTALLATION
Fig. 5 – Cast Iron Damper
1.  Remove damper from collar by pulling handle
out of assembly
2. Attach damper gasket to bottom of collar.
3. Position collar onto hole in stove top and align
the mounting holes.
4. Secure the collar to stove with bolts and nuts
supplied (figure 5).
5. Install damper on angle into collar as shown in
lower illustration (figure 5).
6. Insert damper handle through collar into
damper and out the opposite side of collar.
NOTE: After installation, damper must be able
to open fully and close to 75 – 80%