Sterling Home Theater Server 882.00249.00 Manuale Utente

Pagina di 70
2–Pump 12-Station Controllers 
Chapter 2:  Functional Description 
12 
2-5 Safety 
Devices and Interlocks 
This section includes information on safety devices and procedures that are inherent to the 
Controller. This manual is not intended to supersede or alter safety standards established by 
the user of this equipment. Instead, the material contained in this section is recommended to 
supplement these procedures in order to provide a safer working environment. 
At the completion of this section, the operator and maintenance personnel will be able to do 
the following: 
•  Identify and locate specific safety devices. 
•  Understand the proper use of the safety devices provided. 
•  Describe the function of the safety device. 
Safety Circuit Standards 
Safety circuits used in industrial systems protect the operator and maintenance personnel 
from dangerous energy. They also provide a means of locking out or isolating the energy for 
servicing equipment. 
Various agencies have contributed to the establishment of safety standards that apply to the 
design and manufacture of automated equipment. The Occupational Safety and Health 
Administration (OSHA) and the Joint Industrial council (JIC) are just a few of the 
organizations that have joined with the plastics industry to develop safety standards. 
Every effort has been made to incorporate these standards into the design of the conveying 
system; however, it is the responsibility of the personnel operating and maintaining the 
equipment to familiarize themselves with the safety procedures and the proper use of any 
safety devices. 
Fail Safe Operation 
If a safety device or circuit should fail, the design must be such that the failure causes a 
“Safe” condition. As an example, a safety switch must be a normally open switch. The switch 
must be held closed with the device it is to protect. If the switch fails, it will go to the open 
condition, tripping out the safety circuit. 
At no time should the safety device fail and allow the operation to continue for example, if a 
safety switch is guarding a motor, and the safety switch fails, the motor should not be able to 
run. 
Safety Device Lock-Outs 
Some safety devices disconnect electrical energy from a circuit. The safety devices that are 
used in this Controller are primarily concerned with electrical power disconnection. 
WARNING!  Always disconnect and lockout all electrical power and pneumatic (i.e. compressed air) 
sources prior to servicing the 2-Pump, 12-Station Controller. Failure to do so may 
result in serious injury. No one but the person who installed the lockout may remove 
it.