Sterling Doll BF3-600 Manuale Utente

Pagina di 67
Digital Dosing Units 
25
Step 4: 
 
 
 
 
 
1.  Press 
 a fourth time.   
2.  The machine displays a flashing   and “g”.  
3.  After “4” flashes quickly on the screen, a number in the format xxx.xx will come 
up on the display.   
•  Enter the calibration weight in grams or pounds.  If the calibration weight is 
unknown, enter “00.00” and complete the calibration procedure (section 
3.6) to obtain the correct value.  Upon completion of the calibration 
procedure, the calibration weight will automatically be updated into the 
recipe.  The range of values that can be entered in this field is 00.00 to 400.0. 
Step 5: 
•  Press 
 a fifth time to return to the totalizer. 
 
 
 
Operation –Extrusion Proportional 
 
;
  Ensure that the unit is properly installed (Section 3.1)  
;
  A recipe is entered (“Recipe Input-Extrusion Proportional” Section ) 
;
  The feeder is calibrated (Section 3.6), before attempting to begin operations. 
1.  If desired, clear the totalizer by pressing 
 continuously for 5 seconds until 
the display is reset to “00.00.” 
or