28
•  The disc will rotate one full revolution.  After the disc has stopped rotating, a 
number in the format “xx.xx” will appear on the screen along with a flashing   
and “g.” 
Step 4: 
 
 
 
•  Enter the weight, in grams using the Arrow Keys 
 
 
 
•  Empty and replace weighing container in calibration box (or under material 
outlet tube) 
 
     
 
 
Step 5: 
•  Repeat steps 3 and 4 four (4) more times.   
•  Notice that the displayed calibration weight may change after each sample 
weight is entered.   
•  The value is an average of all the weights entered.  No calculations are 
required.  It can happen that the calculated speed is either too high or low 
causing alarm A0009. Check the recipe and settings and modify if necessary. 
Step 6: