Snom 4S Manuale Utente

Pagina di 68
snom technology AG  •  51
5. 
Web Server 
Integration
The  SBC  can  use  a  web  server  as  application  server.  This  way 
you can use PHP, ASP and anything you like to implement the logic for 
your SIP traffic. For example, if you want to redirect a call to a specific 
gateway, you can do this easily on the web server. The SBC will just use 
the results that come from the web server to the further processing of the 
SIP request.
The SBC divides the interface to the application server into three 
areas:
• 
Authentication. Incoming requests are checked against a password 
list. If the user agent is not present in the local internal database, 
the SBC talks to the application server to update the information.
• 
Registration. When a user agent wants to register its contact, the 
SBC updates the registration information in the application server.
• 
Calls. When a new call is requested by a user agent, the SBC talks 
to the application server. The application server may route the call, 
change From and To-header, set the maximum call duration or re-
ject the request. 
The  filter  talks  asynchronously  to  the  web  server.  That  means, 
the processing of other requests is not blocked by the request. Also the 
processing of other web requests is also not blocked by another web re-
quest. The request is only made at the beginning of a call; further mes-
sages inside the call will not cause additional web requests.
Please use the complete form for the server settings, including 
the  “http://”  in  front  of  the  host  name.  The  filter  supports  only  DNS  A 
resolution for locating the web server; no http proxy is allowed.
5
.