62 • SNMP
[  
S N O M
  4 S   N A T   F
I L T E R
  ]
space etc.), the setup is a little bit more difficult that the setup of a stan-
dard sensor.
A readable parameter is described by its object identifier (OID). 
The object identifies are described in the next paragraph. Please enter the 
OID in your tool and select appropriate names for them. Also make sure 
that the IP address of the host running the SNMP tool matches the setup 
that you gave the SBC in the “Trusted IP Addresses” setting.
The SBC does not support “snmpwalk” or other tools that auto-
matically describe the abilities of the SBC. You must enter these settings 
manually.
6.3.  Available OID
The following table describes the available OID. An absolute value 
describes the current state on the SBC, the value might go up and down. 
Relative values only go up and accumulate the values.
OID
Description
Absolute Unit
1.3.6.1.2.1.7526.1.1
Open Calls
Yes
Calls
1.3.6.1.2.1.7526.1.2
Registrations
Yes
Registrations
1.3.6.1.2.1.7526.1.3
Minutes
No
Minutes
1.3.6.1.2.1.7526.1.4
Received Media
No
Bytes
1.3.6.1.2.1.7526.1.5
SIP Packets
No
Packets
1.3.6.1.2.1.7526.1.6
SIP Traffic
No
Bytes
1.3.6.1.2.1.7526.1.7
Successful Calls
No
Calls
1.3.6.1.2.1.7526.1.8
Unsuccessful Calls
No
Calls
The minutes are measured only for the codecs ulaw, alaw, G.726 
(32 kbit/s), GSM 6.10, G.723.1 and G.729. The minute measurement is 
done by looking at the media type in the RTP packet. If the packet uses a 
non-standard mapping, the results may be inaccurate. 
The SBC measures only the received traffic. Usually, this is equal 
to the sent traffic, because the SBC does not block traffic. However, when 
there is a problem with the media establishment, the number of transmit-
ted bytes might differ from the number of received bytes. The information 
does not include IP header like the UDP header.