Sigma Gold TDP-52-SN3 Manuale Di Servizio

Pagina di 183
27.1.1999 
8HDS50GB_fm5.f
38
Product: HDS-50 (Ext. Handset With Cradle) /      
7.4.3 Connector XIN Signals
7.4.4 Microphone
7.4.5 Speaker
7.4.6 Hook
The hook operation is done by use of a reed switch. Hook operation is connected to 
the handset earphone terminal.
The operation is as follows:
1
ERP
earphone input, HOOK state
2
GND
ground
3
GND
ground
4
MIC
microphone output
Sensitivity:
-43 dB ± 6 dB
Vendor and part no:
Hosiden KUC2023 or KUB2023
RF decoupling capacitor:
33 pF; Size: 0805; Mounted on the microphone 
element.
Sensitivity
95 dB ± 5 dB
Vendor and part no:
Hosiden KDR0928-IE-0030
Impedance:
min 120 ohm
Resistance (DC):
max 3 kohm
ON_HOOK
HIGH DC IMPEDANCE (SWITCH OPEN)
OFF_HOOK
LOW DC IMPEDANCE (SWITCH CLOSED), 2.2 KOHM RESIS-
TANCE