7.  SPECIFICATIONS
G85139-H1750-U049-B
© Siemens plc 1997
26/09/97
36
Input frequency:
47 Hz to 63 Hz
Power factor:
λ
 
 0.7
Output frequency range:
0 Hz to 400 Hz
Resolution:
0.01 Hz
Overload capability:
150% for 60 s, related to nominal current
Protection against:
Inverter overtemperature
Motor overtemperature
Overvoltage and undervoltage
Additional protection:
Against short-circuits and earth/ground faults pull-out protection.
Protection against running with no load (open-circuit)
Operating mode:
4 quadrants possible
Regulation and control:
Voltage/frequency curve
Analogue setpoint / PI Input:
0 - 10 V/2 - 10 V (recommended potentiometer 4.7 k
Ω
)
Analogue setpoint resolution:
10-bit
Setpoint stability:
Analogue < 1%
Digital < 0.02%
Motor temperature monitoring:
l
2
t control
Ramp times:
0 - 650 s
Control outputs:
1 relay 110 V AC / 0.4 A; 30 V DC / 1 A
WARNING: External inductive loads must be suppressed in an
appropriate manner 
(see section 2.1 (5)).
Interface:
RS485
Inverter efficiency:
97% (typically)
Operating temperature:
0
o
C to +50
o
C
Storage/transport temperature:
-40
o
C to +70
o
C
Ventilation:
Fan-cooled
Humidity:
90% non-condensing
Installation height above sea level:
< 1000 m
Note:
If the Inverter is to be installed at an altitude >1000m,
derating will be required.(Refer to DA 64 Catalogue)
Degree of protection:
Frame size A:
IP20
(NEMA 1 using accessory kit - 
see options)
Frame sizes B & C: IP20 (NEMA 1)
(National Electrical Manufacturers’ Association)
Protective separation of circuits:
Double insulation or protective screening
Electro-magnetic compatibility (EMC):
See section 8.3
Options / Accessories
Additional RFI suppression filter
Clear Text Display (OPM2)
PROFIBUS module (CB15)
SIMOVIS software for control via PC
Output chokes and line chokes
Output filters
IP20 (NEMA 1) Accessory Kit