Siemens 9015 Manuale Utente
2 out of 5 Interleaved
Barcodes
Programmer Reference Guide
U26169-J-Z716-1-7600
©
S
iem
e
n
s
N
ix
dor
f I
n
fo
rm
at
ions
s
y
s
tem
e A
G
1
995
P
fa
d
: D:
\S
N
I\
M
a
c
k
w
it
z
\u2
61
69\
o
261
69e
\261
69
E
.K
0
6
2 out of 5 Interleaved
The character complement of the 2 out of 5 Interleaved code comprises:
–
10 digits:
0 1 2 3 4 5 6 7 8 9
–
Start/stop characters:
:/; </=
The number of characters is variable but must be even. If the number of characters is odd,
a 0 is prefixed to make it even.
a 0 is prefixed to make it even.
The start/stop characters are programmed with the characters : and ;. Alternatively, the
characters < and = can be used as start/stop characters.
characters < and = can be used as start/stop characters.
In the plain text line, the characters : and ; or < and = are printed for start/stop.
The symbol layout is self-checking. A check digit is not required. If a check digit is to be
used, it must be programmed in the application (and must be modulo 10 with a weighting
of 3).
used, it must be programmed in the application (and must be modulo 10 with a weighting
of 3).
The ratio of wide to narrow elements should be between 2.0 and 3.0. A ratio of 2.5 is recom-
mended for applications.
mended for applications.
The blank zone before and after the barcode symbol should be at least 10 times the width
of a narrow element.
of a narrow element.