TC12 Installation, Commissioning & Maintenance Handbook 
Test / Maintenance Commands 
3.3.3
 
CU (Unit number: 0 - 5) 
Comment: 
Enables the flow counters to be displayed. 
Note:  The counts are stored as words, so only the least significant byte is 
displayed. 
 
3.3.3.67  Occupancy Counters (GOU) 
GOU (Unit number: 0 - 5) 
Comment: 
Enables the occupancy counters to be displayed. 
Note:  The counts are stored as words, so only the least significant byte is 
displayed. 
 
3.3.3.68  Queue Signals (GQU) 
GQU (Unit number: 0 -5) 
Comment: 
Enables the queue signal counters to be displayed. 
 
3.3.3.69  Override Digital Inputs Enable/Disable (GIO) 
GIO = 1 <enter> 
Comment: 
Replaces the reply data with test data entered using the GID 
command - see below. The override can be disabled by entering 
GID = 0 and is also removed when the handset is disconnected.  
 
3.3.3.70  Digital Inputs Override Data (GID) 
GID (Reply byte number: 0-13) = (binary byte: 0 - 11111111) 
Comment: 
Allows test data patterns for up to 13 reply bytes to be entered. The 
data is actually output when the override is enabled using the GIO 
command. 
 
3.3.3.71  Override Digital Outputs Enable/Disable (GOO) 
GOO = 1 <enter> 
Comment: 
Replaces the control data with test data entered using the GOD 
and GTC commands - see below. The override can be disabled by 
entering GOO = 0 and is also removed when the handset is 
disconnected or after the ‘GOT’ timeout has expired (see below). 
With PB392 firmware (issue 4 or later) the GOO command displays 
GOO:2 whilst the override is active. If the special PLD is fitted 
(667/1/12399/106 - VMS + LMU) then the override is not removed 
when the handset is unplugged.  
 
.66  Flow Counters (GCU)
G
666/HE/43100/000  
Page 113 
Issue 9