Siemens Network Hardware SM2 monitoring system Manuale Utente

Pagina di 500
190
U3585-J-Z125-8-76
Activating user task monitoring
SM2 operation
Formats
Operands
TSN =
Specifies the task to be monitored or for which monitoring is to be terminated.
TSN = *OWN
The task invoking the command will be monitored or monitoring of that task will be termi-
nated.
TSN = <alphanum-name 1..4>
The task with the TSN specified is monitored or monitoring of that task is terminated. Only
users who have been assigned the system privilege SW-MONITOR-ADMINISTRATION
can start or terminate monitoring of any tasks. All other users can only monitor their own
tasks.
Restriction: The task SM2U, which processes the user-specific SM2 output files, cannot be
monitored.
FILE =
Specifies the user-specific SM2 output file.
FILE = *STD
The user-specific SM2 output file contains the file attributes which are defined in the
following table.
FILE = *BY-LINK-NAME
The user defines the file name and further file attributes using the corresponding BS2000
commands. The file is assigned via the link name. The link name for the user-specific SM2
output file is PALINK.
START-TASK-MEASUREMENT
TSN = *OWN / <alphanum-name 1..4>
,FILE = *STD / *BY-LINK-NAME
,PCOUNTER-INTERVAL = *NONE / <integer 1..10000>
,LOAD-INFO = *STD / *DETAILED
STOP-TASK-MEASUREMENT
TSN = *OWN / <alphanum-name 1..4>