Siemens Network Hardware SM2 monitoring system Manuale Utente
278
U3585-J-Z125-8-76
PCA DEVICE report
SM2 reports
PCA DEVICE report
This report provides monitored data on the devices of a 3419/21 controller which have been
allocated a cache.
allocated a cache.
Report output
The PCA DEVICE report is output only at the explicit request of the SM2 user with the help
of the SELECT-PCA-CACHE statement (see page 174). This statement is used to output a
PCA CONTROLLER report together with a PCA DEVICE report for the selected cache of
a controller. The PCA DEVICE report supplies detailed information on the devices of a
3419/21 controller which have been allocated a cache.
The report can only be output if the SM2 administrator has activated the monitoring process
using the statement START-MEASUREMENT-PROGRAM TYPE=*PCA.
of the SELECT-PCA-CACHE statement (see page 174). This statement is used to output a
PCA CONTROLLER report together with a PCA DEVICE report for the selected cache of
a controller. The PCA DEVICE report supplies detailed information on the devices of a
3419/21 controller which have been allocated a cache.
The report can only be output if the SM2 administrator has activated the monitoring process
using the statement START-MEASUREMENT-PROGRAM TYPE=*PCA.
Overflow screens may be requested for this report.
The monitored data output is sorted in accordance with the total number of access opera-
tions.
It is possible to output data on up to 32 pairs of controllers and caches.
The monitored data output is sorted in accordance with the total number of access opera-
tions.
It is possible to output data on up to 32 pairs of controllers and caches.
Monitoring information
CTL-DEV-MN
Mnemonic name of the controller’s CONTROL DEVICE
CACHE-ID
Cache ID
CACHE SIZE
Size of the cache MB
DEVICE MN
Mnemonic name of the device supported by the cache
DEVICE VSN
VSN of the device supported by the cache
#
SHAR
Number of systems which service the device via the cache
#
PEND. BLOCKS
Number of blocks (2K/4K blocks, depending on the disk format) yet
to be relocated to disk
to be relocated to disk
D017ZE03 SM2 PCA DEVICE CYCLE: 60 S 99-03-24 11:11:02
CTL-DEV-MN: A93F CACHE-ID: 5 CACHE-SIZE: 20 MB
------+--------+----+-------+-------+--------+-------+-------+--------+--------
DEVICE | # |#PEND. | READ | C-READ | READ- | WRITE |FAST W. |C-OVER
MN | VSN |SHAR|BLOCKS | (1/S) | (1/S) |H-RATE%| (1/S) | (1/S) | (1/S)
------+--------+----+-------+-------+--------+-------+-------+--------+--------
A90A | A90A.0 | 1 | 594 | 324.8 | 324.8 | 100.0 | 178.0 | 178.0 | 0.0
------+--------+----+-------+-------+--------+-------+-------+--------+--------
------+--------+----+-------+-------+--------+-------+-------+--------+--------
DEVICE | # |#PEND. | READ | C-READ | READ- | WRITE |FAST W. |C-OVER
MN | VSN |SHAR|BLOCKS | (1/S) | (1/S) |H-RATE%| (1/S) | (1/S) | (1/S)
------+--------+----+-------+-------+--------+-------+-------+--------+--------
A90A | A90A.0 | 1 | 594 | 324.8 | 324.8 | 100.0 | 178.0 | 178.0 | 0.0
------+--------+----+-------+-------+--------+-------+-------+--------+--------