SCE_EN_040-020_R1209_Startup Programming in High-Level Languages with S7-SCL and SIMATIC S7-300 
 
4.4 
Interface of the block calculate_tankcontent [FC140] 
 
The interface of the block must be declared before the program can be written. In the interface 
declaration, the local tags known only in this block are defined. 
 
The tags or interface parameters are divided into two groups: 
 
 Block parameters that form the block interface for the call in the program. 
Type 
Designation 
Function 
Available in 
Input parameters 
Input 
Parameters whose values are 
read by the block.  
Functions, function blocks, and some 
types of organization blocks 
Output parameters 
Output / 
Return 
Parameters whose values are 
written by the block. 
Functions and function blocks 
In/out parameters 
InOut 
A parameter whose value is read 
by the block when it is called and 
is written back by the block to 
the same parameter after it is 
processed. 
Functions and function blocks 
 
 
 
 Local data that is used for saving intermediate results. 
Type 
Designation 
Function 
Available in 
Temporary local data 
Temp 
Tags that are used to store 
temporary intermediate results. 
Temporary local data is retained 
for one cycle only.  
Functions, function blocks, and 
organization blocks 
Static local data 
Static 
Tags that are used for saving 
static intermediate results in the 
instance data block. Static data 
is retained until it is overwritten, 
which may be after several 
cycles. 
Function blocks