insul-lam
Insul-Lam is used as a non-structural nail base 
in either a one or two layer system. 
two-layer system – Begin by installing the 
2x dimensional lumber dam around the 
perimeter of the roof.  The height of the dam 
is determined by the depth of Insul-Lam being 
installed.  In residential applications, PBS 
recommends the use of a vapor retarder with 
either the one or two layer systems.  You 
will need to cut one 2’ x 4’ foam section 
and enough 2’ x 8’ foam sections from your 
shipment to ring the perimeter flush to your 
lumber dam. 
Once the 2’ sections are in place, layout the 
remaining 4’ x 8’ foam sheets. 
top layer – Apply the nail base top layer 
perpendicular to the foam layer so that joints 
overlap.  You will need to remove 1 1/2” of 
foam along the edges of your perimeter course 
so the OSB overlaps your lumber dam.  Once 
an Insul-Lam top sheet is in position, fasten the 
assembly to the deck with Premier Panel Screws 
following the spacing and frequency determined 
by engineering.  Penetrate the structural deck 
to a depth of at least 1”.  Along the perimeter