Phonetics 1104 Manuale Utente

Pagina di 108
Sensaphone
®
Model 1104 User’
s Man
ual
96
Problem
Cause
Solution
1.  The Model 1104 fails to dial out.
a)
The telephone number may be incorrectly
programmed.
b)
Tone or pulse (the current dialing
method) is not compatible with the
telephone line on which the Model 1104
is installed.
c)
Recognition Time is too long. An alert
condition does not remain in effect long
enough to become a valid alarm.
d)
Max Calls is set to zero.
Recheck programming steps.  
Refer to Chapter 4,  Section 4.2.1.
Switch from the current setting: from tone to
pulse, or from pulse to tone. 
Refer to Chapter 4,  Section 4.3.
Reprogram Recognition Time. Set the
Recognition Time to the minimum duration
required to create a valid alarm. If possible,
test the new setting by deliberately creating an
alert condition. 
Refer to Chapter 5, Section 5.3.
Reprogram Max Calls.  It is a good idea to set
your Max Calls to at least equal the number of
dial-out telephone numbers programmed.
Refer to Chapter 4, Section 4.12.1.
Communications / Dial-out: