18. Liquid Propane Hook-Up 
Attach the regulator (A) to the propane cylinder (B) by 
turning the regulator handle clockwise as shown in fig. 
20. If the outdoor cooking appliance is not in use, the 
gas must be turned “OFF” at the Liquid Propane cylinder.
 
 
 
Check all gas supply fittings for leaks before each 
use. Do not use the grill until all connections have 
been checked and do not leak 
(see “Leak Testing” 
instructions on page 16). 
 
 
INSTALLATION INSTRUCTIONS 
 
GAS HOOK-UP 
 
Only the pressure regulator and hose assembly supplied with the grill should be used. Any replacement 
pressure regulator and hose assembly must be specified by the grill manufacturer. 
 
This grill is configured for Liquid Propane. Do not use a Natural Gas supply. 
 
Total gas consumption (per hour) of the 720-0522 Liquid Propane gas grill with all burners set on “HI”: 
Main burners              50,000 BTU/Hr.                     
Rear burner 
            10,000 BTU/Hr. 
Side burner 
            15,000 BTU/Hr. 
Total 
 
            75,000 BTU/Hr. 
 
The installation of this appliance must conform with local codes or, in the absence of local codes, with 
either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA 
B149.2. 
Installation in Canada must be in accordance with the Standard CAN/CGA-B149.2 (installation code for 
gas burning appliances and equipment) and local codes. 
 
LIQUID PROPANE CYLINDER REQUIREMENTS  
(20-lb Cylinder) 
A dented or rusty Liquid Propane cylinder may be hazardous and should be checked by your supplier. 
Never use a cylinder with a damaged valve. The Liquid Propane cylinder must be constructed and 
marked in accordance with the specifications for Liquid Propane cylinders by the United States 
Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders, 
Spheres and Tubes for Transportation of Dangerous Goods Commission. 
 
The 20-lb cylinder must have a shut off valve terminating in a valve outlet specified, as applicable, for 
connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection 
ANSI/CGA-V-1. 
 
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and 
removed from the outdoor cooking gas appliance. The cylinder system must be arranged for vapor 
withdrawal. The cylinder must include a collar to protect the cylinder valve. 
 
Manifold pressure: (operating) 10 inches water column (W.C.), (non-operating) 11.2 inches water column 
(W.C.). 
 
The Liquid Propane cylinder must be fitted with an Overfill Protection Device (OPD). 
  