TROUBLESHOOTING 
 
 
 
 
 
 
 
 
 
When to Look for Spiders 
You should inspect the burners at least twice a year or immediately after any of the following conditions 
occur: 
1.  The smell of gas in conjunction with burner flames appearing yellow. 
2.  The grill does not reach temperature. 
3. 
The grill heats unevenly. 
4. 
The burners make popping noises. 
 
BEFORE CALLING FOR SERVICE 
If the grill does not function properly, use the following checklist before contacting your dealer for service.  
You may save yourself the cost of a service call. 
 
 
 
Problems 
What To Do 
Grill will not light when the control knob is rotated. 
 
 
•  Check to see if the Liquid Propane cylinder is 
empty. 
•  Clean wire(s) and/or electrode with rubbing 
alcohol and a clean swab. Wipe with a dry 
cloth. 
•  Make sure the wire is connected to the 
electrode assembly. 
•  Check to see if the other burners operate. If so, 
check the gas orifice on the malfunctioning 
burner for an obstruction. 
•  Check for spiders and insects. 
Burner flame is yellow or orange in conjunction 
with gas odor. 
•  Check for spiders and insects 
•  Call customer service at 1-877-323-5263. 
Low heat with the control knob on the “HI” setting. 
•  Check to see if the fuel hose is bent or kinked. 
•  Make sure the grill area is clear of dust. 
•  Make sure the burner and orifice are clean. 
•  Check for spiders and insects. 
•  The regulator has a safety device that restricts 
the flow of gas in the event of a leak.  This 
safety device can be triggered without a gas 
leak.  To reset the safety device, turn all 
burners “OFF” and close the Liquid Propane 
cylinder valve.  Disconnect the regulator from 
the Liquid Propane cylinder and wait 1 minute.  
Reconnect the regulator to the Liquid Propane 
cylinder and slowly open the valve until the 
valve is fully open.  Light all burners and 
observe the temperature. 
  WARNING 
Spiders and insects can nest inside the burners of the grill and disrupt gas flow. This very 
dangerous condition could cause a fire behind the valve panel, thereby damaging the grill and 
making it unsafe for operation. Inspect the grill at least twice a year. 
 