Toshiba MJ-1103 Manuale Utente
6
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
MJ-1103/1104
TROUBLESHOOTING
6 - 23
6.3
Other Errors
6.3.1
Stapler related error
[EA50]
Stapling jam
Is there any paper remaining on the transport path in the finisher or equipment, or on the finish-
ing tray?
ing tray?
YES Remove
the
paper.
NO
Is the jam cleared by taking off the staple cartridge from the finisher and removing the staple
sheet slid from the staple case?
Is the jam cleared by taking off the staple cartridge from the finisher and removing the staple
sheet slid from the staple case?
YES End.
NO
Is there any mechanical problem when the actuator of the stapler interference sensor (S11) is
moved?
Is there any mechanical problem when the actuator of the stapler interference sensor (S11) is
moved?
YES Reinsert the clip which fixes the actuator from the side of it.
NO
Is the harness between the stapler and the finisher control PC board (CN19) disconnected or
open circuited?
Is the harness between the stapler and the finisher control PC board (CN19) disconnected or
open circuited?
l
YES • Reconnect
the
connector securely if there is any disconnection.
• Replace the harness if open circuited.
NO
Are the harnesses in the stapler disconnected or open circuited?
Are the harnesses in the stapler disconnected or open circuited?
l
YES • Reconnect
the
connector securely if there is any disconnection.
• Replace the harness if open circuited.
NO
Replace the finisher control PC board (FIN).
Replace the finisher control PC board (FIN).
[CB50]
Stapler home position error
* The [CB50] error also occurs when the error [EA50] has occurred consecutively for 3
times.
Is the harness between the stapler and the CN19 of the finisher control PC board (FIN) discon-
nected or open circuited?
times.
Is the harness between the stapler and the CN19 of the finisher control PC board (FIN) discon-
nected or open circuited?
l
YES • Reconnect
the
connector securely if there is any disconnection.
• Replace the harness if open circuited.
NO
Is any of the harnesses in the stapler disconnected or open circuited?
Is any of the harnesses in the stapler disconnected or open circuited?
l
YES • Reconnect
the
connector securely if there is any disconnection.
• Replace the harness if open circuited.
NO
Replace the finisher control PC board.
Replace the finisher control PC board.