SWRA004A
TRF1500 Integrated Dual-Band RF Receiver User’s Guide
53
3)  Set the spectrum analyzer to measure at the IF frequency (see
Table 5).
4)  Connect the EVM IF output port, J31, to the spectrum
analyzer.
5)  Measure the IF output power (IF P
out
) at the IF frequency with
the spectrum analyzer.
6)  Calculate the Cascaded Gain as:
Gain = (IF P
out
 - RF P
in
) + Transformer Loss. The
transformer loss is 1.8dB.
Low-Band Transmit Mixer: Noise Figure
Control state: 010100
SEE APPENDIX A: TEST BENCH SETUPS
Test setup Figure 22
The cascaded Noise Figure (NF) is measured at the EVM Low
Band IF output port, J31. The measurement is performed using an
HP8970B Noise Figure Meter.  The IF output of the mixer is
converted from differential to single ended using a transformer
balun. The noise figure meter requires a special setup and
calibration since the RF source and receive frequencies are
different.
Set up the noise figure meter as follows:
1)  Special Function 1.4 sets the noise figure meter to measure
variable IF and fixed LO frequencies.
2)  The IF start, stop, and step size frequencies are set to
114MHz, 120MHz, and 3MHz respectively.
3)  Set the smoothing to 16 or above.
4)  Ensure that the Excess Noise Ratio (ENR) Table on the Noise
Source head in use is entered on the NF meter.
a)  On the front panel, press the ENR button.
b)  Check the ENR value by pressing the Enter button or enter
the ENR value for each frequency.
c)  After entering the ENR for the desired frequency, press the
Frequency button on the front panel to exit.
5)  To calibrate the NF Meter:
a)  Connect the Noise Source directly to the NF meter; press
the calibration button twice.