Telect MDC-CB Manuale Utente

Pagina di 50
Telect, Inc. • USA +1.509.926.6000 • Mexico +1.52.33.3836.3700
Poland +1.48.713.239.100 • UK +1.44.1489.889500 • www.telect.com
Copyright © 2002 Telect, Inc., All Rights Reserved
Page 1-3
.
MDC-CB W
ITHOUT
 R
EAR
 C
OMPARTMENT
 S
PLICING
Cabling without in-cabinet splicing involves an aerial or below-ground splice box for splicing the distribution and feeder cables to 
connectorized cabinet cabling. 
At the cabinet, the OSP distribution cable is clamped at the floor of the rear compartment and then routed along the cabi-
net’s compartment partition. The connectorized 250 µm strands break out here into subunits/buffers and then connected to 
one of the six possible, 72-channel Patch Modules. Each patch module contains SC/APC adapters to interface the distribu-
tion fiber in the rear compartment to the cross connections in the front compartment.
Feeder cable is anchored along the rear side wall where 900 µm fiber breaks out into subunits/buffers and routed to 16 
SC/APC interface adapters near the top of the cabinet.
Each SC/APC adapter at the top of the cabinet serves to feed the fiber signal to a blue jumper in the front compartment, shown in the 
preceding illustration. The blue jumper is routed down through the right portion of the front compartment, then around a couple of 
spools and an arc. The two spools at the bottom route the blue fiber to a Telect Splitter Module.
Up to 18, 1x4, 1x8, 1x16, or 1x32 Telect Splitter Modules can be installed in the splitter bulkhead at the bottom of the front compart-
ment. Each splitter module consists of the splitter, one blue “input” jumper, and either 4, 8, 16, or 32 yellow “output” jumpers. All are 
2 mm jumpers, 2.1 m in length.
Splitter module installation and all of the distribution changes occur in this front compartment:
Unassigned jumpers are routed via spools and arcs to a parking station for later subscriber assignment.
Assigned jumpers are routed via the spools and arcs to the front of the SC/APC adapters in the front of the patch modules 
for cross connection to the distribution fiber connected to the rear of the patch modules.
Front View With Door Open
*
Feeders
Assigned 
Distribution
to Subscriber
Unassigned
Distribution
(Parking)
Splitter
Bulkhead
2 mm Jumpers
Splitter Module
OSP
Distribution
Cable
OSP Feeder
Cable
Subunit/Buffer 
From Feeder 
Cable Breakout 
to Rear-Side 
Feeder 
Adapters
Fiber Furcated 
From Multifiber 
Buffer to 
900-
µm
 Single 
Fiber Loose 
Tubing
Rear View With Door Open
*
*  Splitter and Patch Modules are sold separately.