Nortel Networks Video Gaming Accessories 553-3001-211 Manuale Utente

Pagina di 896
 NT8D09 Analog Message Waiting Line card
 Page 545 of 894
Power requirements
Table 175 provides the power requirements for the NT8D09 Analog Message 
Waiting Line card.
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning is not provided on 
the NT8D09 Analog Message Waiting line card. When the card is used to 
Table 175
Power requirements
Voltage
(+/-)
Tolerance
Idle
current
Active
current
Max
+ 12.0 V dc
0.36 V dc
48 mA
0 mA
48 mA
+ 8.0 V dc
0.40 V dc
150 mA
8 mA
280 mA
–48.0 V dc
2.00 V dc
48 mA
40 mA
688 mA
–48.0 V dc
5.00 V dc
0 mA
10 mA
(Note 1)
320 mA
86.0 V ac
5.00 V ac
0 mA
10 mA
(Note 2)
160 mA
–150.0 V dc
3.00 V dc
0 mA
2 mA
32 mA
Note 1: Each active ringing relay requires 10 mA of battery voltage.
Note 2: Reflects the current for ringing a single station set (or DN 
telephone). There may be as many as five ringers on each line.