Power requirements
Table 199 lists the power requirements for the E&M trunk card.
Signaling type
Loop
Ground or loop start
Far-end battery
-42 to -52.5 V
-42 to -52.5 V
Near-end battery
N/A
-42.75 to -52.5 V
Minimum loop current
N/A
20 mA
Ground potential difference
+ 10 V
+ 3 V
Low DC loop resistance
during outpulsing
during outpulsing
N/A
300 ohms
High DC loop resistance
N/A
Ground start equal to or
greater than 30 kS. Loop start
equal to or greater than 5 MS
greater than 30 kS. Loop start
equal to or greater than 5 MS
Line leakage
Equal to or greater than 30
kS (Tip to Ring, Tip to GND,
Ring to GND).
kS (Tip to Ring, Tip to GND,
Ring to GND).
Equal to or greater than 30
kS (Tip to Ring, Tip to GND,
Ring to GND)
kS (Tip to Ring, Tip to GND,
Ring to GND)
Effective loss
See pad table
See pad table
Table 199
Power requirements
Power requirements
Voltage
Tolerance
Max current
+15.0 V dc
±5%
200 mA
–15.0 V dc
±5%
200 mA
+8.5 V dc
±2%
200 mA
–48.0 V dc
±5 %
415 mA
Table 198
Electrical characteristics of trunk cards (Part 2 of 2)