Automatically turn station on when system starts: If you unset this checkbox 
the  station  (and  its  monitor)  will  not  start  when  the  system  boots  up.    This  is 
normally left defaulted to on; otherwise, you will have to manually start the station 
from this administration console. 
• 
Enable “Shut Down” option without logging on to the station: If this is turned 
on, access terminal users see the shut down options in their logon window and 
their “Start” programs tab. This would allow the host PC to be shut down without 
a valid user logon. If this is turned off, the shut down options are not visible until 
the user logs on. 
• 
Monitor off: An individual X550 access device station consumes less than one 
watt  of  power,  but  the  monitor  attached  to  it  consumes  many  times  that  (50-70 
watts  for  an  LCD  monitor  and  well  over  100  watts  for  a  CRT).    Thus  the  X550 
PCI  card  provides  an  EXTRA  “energy  saver”  setting  that  is  independently 
configurable for each access device or station..  This drop down sets the amount 
of time the station can be idle before the X550 puts the monitor into a sleep state.  
Moving the mouse or hitting a key on the keyboard attached to the corresponding 
access  device  will  wake  the  monitor  back  up.    Selecting  the  value  of  “Never” 
means that the monitor will always remain powered on. (All normal screen saver 
functions still apply to prevent monitor “burn.”) 
• 
Enable “Auto Logon” mode: When this is enabled and there is an entry in the 
“username”  and  “password”  fields,  the  specified  username  is  automatically 
logged in when the station starts. 
• 
Run this program only during Logon: and In folder: 
When you select a program to run and the folder where it is located, the program 
is  started  when  there  is  a  logon  using  the  station.  (This  option  along  with  the 
Enable Auto Logon are often used in setting up unattended kiosk environments.) 
• 
Initial  keyboard  state:  These  check  boxes  allow  setting  the  specific  keyboard 
states that will be active when the stations starts. There are separate settings for 
Num-Lock, Caps-Lock and Scroll-Lock. 
In the toolbar, there is a “Stop station button:.” When you select a station and click this 
button,  a  confirmation  window  asks  if  you  want  to  stop  the  selected  station.  It  also 
reminds you to exit all programs and log off the station.