NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
Page 186
NDA-24297, Issue 1
C-17D
Consultation Hold - All Calls - D
term
Programming (cont’d)
System Data 1, Index 157. Trunk Soft Hold Timer A, used with senderized trunks. Assign data 00H for
a value of 18 seconds. (Data 31H may be used for a value of two seconds, if CALL TRANSFER-ALL
CALLS [C-11] is to be used immediately after connecting to the trunk.). This is the time between trunk
connection and when switch hook flash is allowed on a senderized trunk connection. It is also used to
determine when SMDR billing will begin.
System Data 2, Index 1, Bits 0 & 1. CONSULTATION HOLD allowed or denied? 00: Denied; 01:
Originating and Terminating Calls allowed, Tandem Call denied; 11: All calls allowed. Normally
assign data “11”.
System Data 3, Index 2, Bits 0-3. Switch hook flash starts timer. To calculate this value: (1~FH) x 120
msec = Timer.
System Data 3, Index 2, Bits 4-7. Switch hook flash ends timer. To calculate this value: (1~FH) x 120
msec = Timer. For both beginning and ending timers, assign 91H for 120 - 1080 msec.
FCCS Programming 
No unique programming is required for the FCCS network.
Note:
System timers may be set on a network basis in ASYDN.
f (t)
0 ms
Bit 0-3
120 ms
No Detection
Bit 4-7
1080 ms Disconnection