NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 215
Call Waiting - Originating
C-31
Service Conditions (cont’d)
EXCLUSIVE HOLD - D
term
[E-4D]
EXECUTIVE RIGHT-OF-WAY
[E-1, E-8]
NON-EXCLUSIVE HOLD - D
term
[N-7D]
OFF-HOOK QUEUING
[O-7]
OUTGOING TRUNK QUEUING
[O-2, O-2D]
PRIVACY - D
term
[P-14D]
PRIVACY RELEASE
[P-18]
THREE-WAY CALLING
[T-2, T-2D]
VOICE CALL - D
term
[V-2D]
21.
The following service features take precedence over CALL WAITING - ORIGINATING:
CALL FORWARDING - ALL CALLS
[C-5]
CALL FORWARDING - BUSY LINE
[C-3]
STATION HUNTING - CIRCULAR
[S-7]
STATION HUNTING - SECRETARIAL
[S-8]
STATION HUNTING - TERMINAL
[S-9]
Interactions
1.
When Station A directs the second CALL WAITING-ORIGINATING to a given station, Station A will
receive reorder tone.
2.
A CALL WAITING-ORIGINATING call is answered by flashing the switch hook of a single-line set or
pressing the ANSWER or TRANSFER keys of a D
term
. CALL TRANSFER-ALL CALLS [C-11] is not
allowed. If the TRANSFER key on a D
term
or the switch hook is flashed on a single-line set, the
SPLITTING-D
term
[S-4D] feature is being used.
3.
CALL WAITING-ORIGINATING is denied toward a TIE Line.
Programming
STEP 1:
ASYD
- System Data 1, Index 152. Interval for CALL WAITING-ORIGINATING. Indication Tone
to be sent to the destination telephone. Timer Class 3 = 2 seconds. MTC x TC = Interval for CALL
WAITING-ORIGINATING. MTC assigned in hexadecimal to Bits 0-3 of this Index. Default value is
10 seconds.
Example: Data 36H is assigned.
2 x 6 = 12 second intervals
TC x MTC = Timer
System Data 2, Index 10, Bit 4. Is CALL WAITING-ORIGINATING access code to be dialed before
the station number? This will activate the feature automatically upon encountering a busy station. 0/1:
No/Yes.
Note:
Index 10, Bits 4 and 6 are mutually exclusive. Once Bit 6 is assigned data “1”, Bit 4 is not needed.
System Data 2, Index 10, Bit 6. Should CALL WAITING-ORIGINATING operation be automatic
upon encountering a busy station? If yes, no access code is required for operating the feature. 0/1: No/
Yes. Assign on a per-tenant basis.
System Data 2, Index 10, Bit 7. Should the Warning Tone set in System Data 1, Index 152 be
periodically sent? 0/1: No/Yes.
System Data 3, Index 3, Bit 5. Enable ringer pattern 5.
System Data 3, Index 7. Default data provides for four seconds ON, two seconds OFF for
DISTINCTIVE RINGING [D-10].