NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
Page 234
NDA-24297, Issue 1
C-75
Call Forwarding - Intercept / Announcement - Attendant
Programming
Programming of hardware into system data is required. Refer to CALL FORWARDING-
INTERCEPT/ANNOUNCEMENT
. Timers are also programmed into system data (see
VARIABLE TIMING PARAMETER
).
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
ALRTN
- This data must be assigned to the NCN.
Assign the logical route number to the physical route.
STEP 2:
AAEDN
- This data must be assigned to the NCN.
Assign the announcement equipment data.
UGN: User Group Number
EQP:
Announcement Equipment Number
0 = Dead Level
1 = Unused Number
2-15 = Announcement service
C:
Duration of Connection
0 = Disconnection occurs in 30 seconds
1 = Connection is held until the station is released. See the requirements of the application for
the announcement equipment. For Dead level applications, assign data “0”.
R:
Sending RBT
0/1 = Yes/No
A:
Answer Signal Sending (Answer from the incoming trunk)
0 = No/Yes Normally assign data “1”.
M:
Multiple Connection
0/1 = Single Connection/Multiple Connection
LGRT: Logical Route Number
TK:
Trunk Number
*Not necessary for “M = 1”
STEP 3:
ARRCN
- This data must be assigned to the NCN.
Release the restriction between the terminating trunk and the announcement trunk.
STEP 4:
ARSCN
- This data must be assigned to the NCN.
Release the restriction between the announcement trunk and the station.
Note:
The current command data shown is set to all nodes using the service: ASTD, ARTD, ATRK, MBTK