NEC 2400 PX Manuale Utente
NEAX2400 IPX Feature Programming Manual
Page 328
NDA-24297, Issue 1
D-153
Distinctive Ringing - Caller ID
Service Conditions (cont’d)
13.
Ringer patterns 2, 3 or 4 cannot be assigned for this feature. When one of those ringer patterns is assigned
from the MAT, default value “Ringer pattern 6” is automatically set.
from the MAT, default value “Ringer pattern 6” is automatically set.
14.
When System Data 3 is changed, circuit card (LC,ELC) initialization is required.
15.
The following circuit card is required for Analog Caller ID:
16.
When the multiple incoming calls are simultaneously terminated to the multi-line on the D
term
, the priority
of ringing pattern is as follows:
Programming
STEP 1:
ASYD
- System Data 1, Index 417, Bit 0. Recall Ringer Pattern for CALL BACK [C-1], CALL
WAITING - ORIGINATING [C-31], and OUTGOING TRUNK QUEUING [O-2].
0/1 = Ringer pattern 5/Ringer pattern 1.
System Data 3, Index 0. Assign Timer Value for Ringer Pattern 0.
System Data 3, Index 0. Assign Timer Value for Ringer Pattern 0.
System Data 3, Index 1: Assign Timer Value for Ringer Pattern 1.
System Data 3, Index 3, Bit 0. 2 Burst on the ON Time for Ringer Pattern 0. 0/1 = Not required/
Required.
System Data 3, Index 3, Bit 0. 2 Burst on the ON Time for Ringer Pattern 0. 0/1 = Not required/
Required.
System Data 3, Index 3, Bit 1. 2 Burst on the ON Time for Ringer Pattern 1. 0/1 = Not required/
Required.
System Data 3, Index 3, Bit 5. 3 Burst on the ON Time for Ringer Pattern 5. 0/1 = Not required/
Required.
Required.
System Data 3, Index 3, Bit 5. 3 Burst on the ON Time for Ringer Pattern 5. 0/1 = Not required/
Required.
System Data 3, Index 7: Assign Timer Value for Ringer Pattern 5.
System Data 3, Index 8: Assign Timer Value for Ringer Pattern 6.
System Data 3, Index 8: Assign Timer Value for Ringer Pattern 6.
System Data 3, Index 9: Assign Timer Value for Ringer Pattern 7.
STEP 2:
ACID
- Assign the calling number for this service.
TYPE: 1
TN:
Tenant number
STN:
Station number
CID:
Calling number (Maximum 28 digits)
SRV:
6 (Distinctive Ringing - Caller ID)
RGP:
Ringer pattern (0, 1, 5 - 7)
FCCS Programming
No unique programming is required for the FCCS network.
CIRCUIT CARD NAME
REMARKS
PA-8COTBJ
PRIORITY
1ST
2ND
3RD
4TH
5TH
Ringing pattern
RG7
RG6
RG5
RG0
RG1