NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 445
LCR - Time Of Day Routing
L-10
FCCS Programming (cont’d)
Route Number (RT) - The physical Route Number to be selected.
Skip Digits (SKIP) - The digits to be skipped when translating the dialed digits in AFRS. If ARTD is
assigned as shown, at a minimum, always assign “1” to skip the LCR (S) access code.
Pattern Number Location (PNL) - If digits are to be added after translating the dialed digits in AFRS,
go to the AADC command.
Overflow Tone (OVFT) - Assign if a tone is wanted for the Last Choice Route.
Priority Restriction Class (PRSC) - Refer to PRIORITY RESTRICTION CLASS in the EPN Features
and Specifications. If this is required, assign PRSC here; classes 1-15.
STEP 2:
ATCPL
- A maximum of eight Time-of-Day Pattern changes (0-7) are available, whereby the system
will refer to different OPR assignments as a function of time. As a result, different routes will be listed
per OPR and will require different assignments in ASDC.
Assign the following:
Time Setting
TO:
FROM: (In military time, and only on the half hour and hour)
PATTERN NUMBER: (0-7).