NEAX2400 IPX Feature Programming Manual
Page 480
NDA-24297, Issue 1
M-18
Maintenance Administration Terminal (MAT)
Service Conditions (cont’d)
b.) The maximum digits of the USER NAME is 16, and those of the ID CODE is 8.
c.) Lock Out information is output with the information of the USER NAME, date, time, and IOC
port used as System Message.
d.) A maximum of 128 System Messages can be stored. However, if other failure messages are
output, the stored number for Audit Trail to Track the Mat Usage service will decrease.
e.) If more than 128 System Messages are output, the exceeded messages will not be stored.
f.) When a System Message is printed out, that information remains as OLD information.
11.
Multiple MAT connection is available via RS-232C or TCP/IP interface. The allowed MAT number is as
follows:
RS-232C:
Maximum of 2
TCP/IP:
Maximum of 4
Note
Note:
The number of ports provided by TCP/IP is a maximum of 5. For this reason, if the ports (2 or more ports)
are occupied by other applications (SMDR, MCI, OAI, MIS, etc.), the allowed MAT number is restricted as
shown below:
12.
The number of ports for TCP/IP is 21. Therefore, restrictions are lifted to use multiple MATs (regardless
of the number of other applications used). A maximum of 4 MATs may be connected per system.
Interactions
1.
AUIDN must be assigned before allowing the password function in the ASYD command. If password is
allowed in ASYD, before AUIDN is assigned, error message 0550, the PASSWORD NOT YET
ASSIGNED will be displayed.
2.
Deletion of a password must begin with ASYD, System Data 1, Index 116, and then the AUIDN
command.
Programming
STEP 1:
AIOC
- Assign the attribute data of the IOC port.
STEP 2:
Assign Terminal Configuration data (Serial Settings / TCPIP Settings) in the PBX Administration
menu.
FCCS Programming 
This data setting describes only the additional or replacement commands used to activate FCCS
services. When used as an FCCS feature, these commands replace the non-network commands (for
example, AAED is replaced by AAEDN). Note that the data setting for FCCS service varies depending
on the node.
STEP 1:
Assign Terminal Configuration data (Serial Settings / TCPIP Settings) in the PBX Administration
menu. Assign the Fusion Point Code of the destination switched in.
TOTAL APPLICATIONS USED
MATS ALLOWED PER SYSTEM
0
4
1
4
2
3
3
2
4
1