NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 595
Periodic Time Indication Tone
P-11
Programming
STEP 1:
ASYD
- System Data 1, Index 137. This timer sets the interval when the first tone will be sent to the
station. Assign 00H for 3 minutes.
System Data 1, Index 138. This timer sets the period between the first and second tones and all other
subsequent tones. Assign 00H for 3 minutes.
STEP 2:
ARTD
- Assign CDN 29:TELP. Flag the routes with which the tone will operate.
STEP 3:
ASFC
- Assign to stations that receive PERIODIC TIME INDICATION TONE a Service Feature
Class that allows SFI 11 and SFI 33.