NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
Page 650
NDA-24297, Issue 1
S-6
Station-Controlled Conference
Programming
STEP 1:
ANPD
- A number level must be reserved for station numbering plan. In an existing system, a station
level will already be established. If a vacant level does exist, it may be used to create 2 or 3-digit
station numbering. For example:
TN: 1
DC: 3
CI: N, H, BNND: 1
BLF: 1-On
STEP 2:
ASPA
- For the desired station numbering assign SRV = STN (Station). For example:
ACC: 3
CI: N, H, B
SRV = STN (Station)
STEP 3:
ASDT
- Assign all ports of the PA-CFTB as DP/PB stations; TEC = 3. Based on the example data
assignments in ANPD, the station numbers will reside in level 3.
Example data assignments. (PA-CFTB located in PIM 1, Group = 03):
STEP 4:
ASHP
- Assign to a STATION HUNTING-TERMINAL [S-9] group the pilot and stations of the PA-
CFTB located on levels 1-7. For example:
TN:
1
STN:
3201
CNT:
7
STN:
3202, 3203, 3204, 3205, 3206, 3207
In this example, Ext. 3201 is the Pilot number of the Conference Bridge. Do not assign the Conference
Leader to this group. Before or after all Conference participants are connected to the PA-CFTB, the
Conference Leader directly calls the Conference Leader Port; for this example Ext. 3200.
PA-CFTB 
PORT
LEN
STATION 
NUMBER
TEC
SFC
RSC
REMARKS
0
001030
3200
3
1
1
Conference Leader
1
001031
3201
3
1
1
Conference
Participant
Ports
2
001032
3202
3
1
1
3
001033
3203
3
1
1
4
001034
3204
3
1
1
5
001035
3205
3
1
1
6
001036
3206
3
1
1
7
001037
3207
3
1
1