NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
Page 36
NDA-24297, Issue 1
A-21
Automatic Trunk Test
Programming
STEP 1:
ANPD
- Reserve a number level for service feature access. Assign for Normal (N), Assign NND in
accordance with a predetermined numbering plan.
STEP 2:
ASPA
- The access code for INDIVIDUAL TRUNK ACCESS must be assigned, SID = 17. Assign
Connection Index, CI = (N) Normal. NND is assigned in accordance with a predetermined numbering
plan.
STEP 3:
ARSC
- A Route Restriction Class (RSC) must be constructed to meet the requirements of the ATT.
These requirements are to allow all outgoing and both way routes*.
STEP 4:
ASFC
- A Service Feature Class (SFC) must be constructed to allow SFI 39, Individual Trunk
Selection.
STEP 5:
ASDT
- A Test Station must be assigned using the RSC and SFC previously constructed. This station
will be a TEC = 3.
STEP 6:
ATTD
- Assignment of Trunk Test Data is used to order the ATT.
STEP 7:
TTLC
- This command will designate the Start route and the End route and trunk numbers. It will be
these trunks that will be tested. Assign the following:
TEST: TEST TYPE
1.
IMMEDIATE EXECUTION
2.
SCHEDULE EXECUTION
RT:
[a] TO [b]: Route Range
a:
Start Route Number
b:
Last Route Number
TK:
[c] TO [d]: Trunk Range
c:
Start Trunk Number
d:
Last Trunk Number
RESULT:[e] - [f]:Tested Route & Trunk
e:
RT at end of test
f:
TK at end of test
START TIME:
15:10
PRESENT TIME:
15:13
Note:
Routes that are used as incoming only, such as DDD or DIT, should be programmed as bothway. Allow only
the RSC of the Test station access to these routes on an outgoing basis for test purposes only.