NEC 2400 PX Manuale Utente

Pagina di 1089
NEAX2400 IPX Feature Programming Manual
Page 818
NDA-24297, Issue 1
B-9
Busy Verification - CCIS
Programming (cont’d)
System Data 2, Index 0, Bit 4. On a per-tenant basis, assign data “1” to enable BUSY
VERIFICATION.
STEP 2:
ASFC
- For stations that permit BUSY VERIFICATION, assign a Class of Service that allows SFI 4,
EXECUTIVE RIGHT-OF-WAY [E-1] and SFI 11, ATTENDANT CAMP-ON WITH TONE
INDICATION [A-45]. SFI: 3 must be allowed for the attendant’s Service Feature Class (normally
SFC: 0) at all locations allowing the attendant to use this feature.
STEP 3:
ATRK
- Assign the LEN as Route 909, Digital Conference Trunk. A LEN consists of the following:
Group and Level numbers for the Digital Conference Trunk are 210, 213, 216, 221, 224, 227, 232, and
235.
STEP 4:
ARSC
- When a station is connected to a trunk, CDN 44:PRV of the route must be assigned as data
“0” for ATTENDANT OVERRIDE [A-7] to be allowed.
XX                X             XX           X
Module Group
Unit
Group
Level