NEC V801 Manuale Utente

Pagina di 72
 
(1/72) 
EXTERNAL CONTROL                          NEC LCD Monitor 
Rev.3.8 
INDEX
 
I. Application ................................................................................3
 
II. Preparation ...............................................................................4
 
2. Connectors and wiring ....................................................................4
 
2.1 RS-232C Remote control ...............................................................4
 
2.2 LAN control ...........................................................................4
 
III. Communication specification...............................................................5
 
3. Communication Parameter ................................................................5
 
3.1 RS-232C Remote control ...............................................................5
 
3.2 LAN control ...........................................................................5
 
3.3 Communication timing .................................................................5
 
4. Communication Format ...................................................................6
 
4.1 Header block format (fixed length) ......................................................7
 
4.2 Message block format .................................................................9
 
4.3 Check code ..........................................................................11
 
4.4 Delimiter ............................................................................12
 
5. Message type ...........................................................................13
 
5.1 Get current Parameter from a monitor. .................................................13
 
5.2 "Get parameter" reply.................................................................14
 
5.3 Set parameter........................................................................15
 
5.4 "Set parameter" reply .................................................................16
 
5.5 Commands...........................................................................17
 
5.5.1 Save Current Settings. ............................................................17
 
5.5.2 Get Timing Report and Timing reply. ................................................18
 
5.5.3 NULL Message....................................................................19
 
IV. Control Commands .......................................................................20
 
6. Typical procedure example...............................................................20
 
6.1. How to change the “Backlight” setting. ................................................20
 
6.2. How to read the measurement value of the built-in temperature sensors...................23
 
6.3. Operation Code (OP code) Table.......................................................26
 
7. Power control procedure .................................................................36
 
7.1 Power status read ....................................................................36
 
7.2 Power control ........................................................................38
 
8. Asset Data read and write................................................................40
 
8.1 Asset Data Read Request and reply ....................................................40
 
8.2 Asset Data write .....................................................................42