3-24  Configuring Your System
Console Redirection
Select "Console Redirection" on the Server menu and press Enter to display the following
screen.
See the table below for setup options on the screen.
Option
Parameter
Description
Your Setting
Serial Console
Redirection
[Disabled]
Enabled
Specifies whether BIOS uses the
specified serial port to redirect the
console to MWA or a remote terminal
using hyper terminal. Disable the Quiet
Boot option in BOOT menu.
Serial Port
COM1 3F8 IRQ4
COM2 2F8 IRQ3
Selects an address/interrupt for the serial
port used for redirection.
Make sure to use the same
address/interrupt as specified in
[Advanced] - [Peripheral Configuration].
Baud Rate
9600
[19.2k]
38.4k
115.2k
Selects a baud rate for communications
with the connected HW console.
[56k] is not available.
Flow Control
No Flow Control
[CTS/RTS]
XON/XOFF
CTS/RTS+CD
Select a flow control method.
[   ]: Factory-set